Or drywall to the top plate and over the gap between the concrete wall and the framed wall.
Fire blocking in exterior walls.
Blocking or nailers used to support fixtures railings cabinets and support of interior and exterior finishes furring strips as permitted in ibc section 803 11 combustible exterior wall coverings balconies and similar projections and bay or oriel windows in accordance with ibc chapter 14.
This provides some additional fire protection benefits and will slow the spread of a fire up a wall by limiting the amount of.
Two layers of 1 by lumber.
Horizontal basement wall fire blocking fire blocking must also be installed every 10 horizontally along the wall irc 302 11 1.
Particleboard covering any seams.
One layer of 3 4 in.
In this video i will explain what fire blocking is and how it works.
These spaces can create drafts that will allow fire to spread readily if not dealt with.
If one should ever occur.
Plywood covering any seams.
The international building code ibc has fire blocking requirements that are intended to limit the spread of flames smoke and gases in combustible concealed spaces such as a wood frame wall cavity.
It s purpose is to prevent the spread of smoke and flames from reaching the bottom of the 1st floor of your home from the basement area thereby burning through and spreading to the 1st floor of the home.
Fire blocking being installed both vertical there are no sill plates anywhere and horizontally although each room runs joists different directions wall bays connect ceiling.
One layer of 3 4 in.
Spaces of masonry or concrete fire wall.
We will also go through some methods used in home construction to prevent the spread of a fire.
Vertical basement wall fire blocking fire blocking basement walls is installed by nailing on strips of 5x8 or thicker o s b.
Materials for fire blocking.
707 2 exc 6 shaft requirement may be eliminated for chimneys when fireblocked 708 4 fireblocking required in fire partitions when not continuous between deck and ceiling 803 4 ftnote a interior finish paneling over furring strips 804 4 1 subfloor construction 1406 2 4 combustible exterior wall veneers.
Fire blocking in stud walls is required in wood framed buildings to stop drafts in the cavities between framing members.
Fire blocking between studs.
In other words these cavities can act like the flue on a fireplace and actually promote the rate in which a fire could grow.
Fire blocking is a blocking device inserted between the top plate of your exterior wall and the exterior masonry wall.
Opening up interior and exterior walls and ceiling reviled a perfect example of chimney walls inside and out connected to ceiling truss bays.